●[Uses] When installing, please match the water tank drain when pressure is opened, so as not to let water get into the ground or main body when dealing pressure. Inlet pipe and filter need to be tightened


Description

Pressure Test PumpPressure Test Pump

11

22

33

44

Pressure Relief Valve

When installing, the pressure release hole must be combined with the water drain hole in the water tank to prevent water from splashing out on the ground or body during pressure release.

Pressure dial

Pressure gauge 55.1 lbs (25 kg) (2.5 Mpa)

High quality insulation

The shell is made of high quality PP material. High temperature resistance, no embrittlement

Explosion-proof pressure tube

High pressure hose, non-aging, non-toxic, lightweight, corrosion resistant

11

How to use pressure resistance test pump

1.Install the machine.Fix the pump body to the tank with 4 screws.

2. Install the water outlet hose, connect one end to the pump body.

(Note: The connection is sealed.Gaskets can also be used with raw material tape.Otherwise, it will leak easily)

3. Connect the other end of the outlet hose to the pipe you are going to test. (Note: Always roll the raw tape up.)

4.Fill the pipeline during the test, let air out and close the pressure relief valve.

5.Fill the water tank with clean water and shake the plate rod up and down to start the pressure test.

6. When the pressure rises to the pressure that needs to read the pressure gauge can be stopped (Normal water pressure is 0.3 Mpa, high rise houses 0.4 Mpa, tap water pressure 0.1 Mpa, 2.2 lbs (1 kg).Water pipe pressure tests are typically raised to 0.8 - 1 Mpa and the pressure test of household plumbing is maintained. 2--4 hours)

7. If the pressure shown on the pressure gauge does not decrease after stopping the back pressure, it proves that the pipeline pressure resistance is good, and on the contrary, the sealing performance of the pipeline is not good, there is a leakage that can cause pressure reduction.

Trouble Causes and Solutions

(1) Move the handle upwards to prevent water absorption.

1.Make sure the suction pipe is clogged with debris.

2.Make sure the switch is tightened.

(2) Feel of sagging when you shake the handle up and down.

1.Check if the switch is tightened.

2. Make sure the sealing ring of the piston pump is damaged.

3. Check the one-way valve on the outlet joint for debris accumulation.

(3) The pressure display on the pressure gauge is not stable

1. If there is a leakage in the pipe or outlet joint, you need to replace the sealing ring.

2. Leak at watch rod connection and replace seal rings;

3. Damaged pressure gaugeRepair pressure gauge

Accessories may vary slightly from lot to lot, please refer to the actual item

  • Note: Do not use in workplace with acid, alkali, corrosive substances