Technical Specifications
For DFC15 controller:
Controller Power Required: 12VDC
Power adapter: Input: 100-240VAC; Output: 12VDC, Maximum 2A
Adapter lead length: 3.3 ft (1 m)
Measurement accuracy: ±1%
Solenoid Valve Output: 12VDC, 5A Max.
Temperature Sensor: 0-125℃/32-257℉, NTC3950, Accuracy: ±1℃/±1℉ Screw: M8
Maximum Weight: 399999 G/L
Quantity Range: 0-999.99 G/L
Flow range: 0-999.99/LPM (GPM)
Cable length: 3.3 ft (1 m)
Dimension: 88mm x 126mm x 30mm
Weight: 7.1 oz (200 g).
Operating Environment: Temperature: 32-122°F; Relative Humidity: <85%
For G3/4" Flow Sensor:
Frequency: F = 5.5 * Q (L/Min)
Flow Range: 3.3 gal (1 - 60 L) / min
Permitted Compression: Water pressure less than 1.75 Mpa
Sensor: Hall effect
Cable Length: 15cm
Error: ±2%
For G3/4 "Solenoid Valve:
Working Pressure: 0.02-0.8 Mpa
How to use:
1 Set K-value, quantity, and maximum alarm value, and install the flow sensor and solenoid valve correctly.
2. Press the RUN/STOP button, the controller will activate, the total will continue to display the current flow and current flow, and the faucet will start to display animation.
3 When the flow rate reaches the set value, the controller automatically turns off the solenoid valve, the total value stops, the faucet animation stops, and the flow rate will return to zero
4 Press the RUN/STOP button again, the controller will repeat the same job.
Note:
1.This controller works with a maximum 5A solenoid valve, but this kit comes with a 2A power adapter. Use the appropriate power adapter if you are driving large solenoid valve.
2, Make sure the direction of the electromagnetic valve and flow sensor is the same as the water flow.
3. Avoid water to the controller.
Package Includes:
1 x DFC15 Controller
1 x G3/4" Flow Sensor
1 x G3/4" Solenoid Valve
1 x Power Adapter
1 x Temperature Sensor
1 x Manual (English language not guaranteed).