Feature

●Size (W x D x H): 1.9 x 1.1 x 4.3 inches (48.1 x 28.8 x 110 mm); Color: Matte Gray
●Material: Mounting frame: Zinc steel, Door: Polypropylene, Cover, Body: Urea Wiring Method: Ground Terminal: Unthreaded Terminal (Wire Inserted), Earth Terminal: Fastening Terminal
●Rating: 15A 125V Compliance Regulation: Electrical Appliance Safety Act (Specified Electrical Appliances)
●Reference Standards: JIS C 8303 (plug connector) / Compatible with: Wire: 600V Vinyl Insulated Wire (IV), 600V Vinyl Insulated Vinyl Sheath Cable (VVF), 600V Flame Resistant Polyethylene Insulated Wire, 600V Polyethylene Cable: Diameter 1.6, 2mm Cu-Single Wire, Earth Terminal Connection: 1. 25-2mm 2 (cord and IV stranded); Diameter 0.06 inch (1.6 mm) Cu single line; Plate: WNS6003H etc. SO-STYLE plate series
●Ambient Usage Temperature: -14 - 104°F (-10 - 40°C)


Description

This is a double ground outlet with an embedded earth terminal.
The surface has a matte finish (grain finish) and is painted on it.
If the surface gets dirty, simply use a mild detergent and wipe it with a soft cloth and wring it out tightly. Clean with mild detergent and dry cloth.

Note:
When wiring, please plug the wire into the deep way. If insufficient insertion is not enough, it may generate heat and may cause burns or fire.
Do not use bent, scratched or tarnished wires. It may generate heat and cause fire.
Make sure to connect wires grounded to the ground terminal (back). Insufficient failure may cause electric shock if the load device connected to the outlet gets leaked.
Do not connect single wire and stranded wire at the same time. If you connect different wires simultaneously, the wires may come out during use, and may cause electric shock when the electrical leakage.

Please install the wall thickness of 7mm or greater. (0.4 inch (9 mm) or more when using an air barrier cover)
For construction without a box, please use scissors hardware (WN3993K020, WN39929020), and push hardware (WN3996020, etc.)
Use WVA7200W exposure box
The box screws should be tightened so that the mounting frame is not deformed.

Use WV2500, WV2501 bar crimp terminals for strands.

This product has a structure that will not connect power if the plug is plugged into a deeper way.
When detecting electricity, please use a detector with a detecting pin length of 0.6 inch (14 mm) or less of 0.08 inch (2 mm) thick. Short circuit may not be able to check the conduction.

Wiring fixtures also have a life span. Depending on the installation location and usage conditions, inspections are especially important for more than 10 years. (Not a product **period)