Feature(may vary by option.)



Description

Product Specifications:
Operating voltage: 6V - 30V, support Micro USB 5.0V input
Operating current: Static current: 50mA
Static current: 15mA
Maximum output load: DC 30V 5A and AC 220V 5A
Trigger signal source: High level trigger (3.0 V - 24.0 V), Low lever trigger (0.0 V - 0.2 V), Switching value control (potential-free contact)
Comes with an emergency stop function (stop key), reverse connection protection
Sleep mode (if you do not operate it for 5 minutes).
How to Use:
Press the SET button and enter the setting interface.
Set the working mode first. Work mode flashes to notify you. Short press the UP/DOWN button to set work mode.
Short press the SET key to select work mode and enter settings.
● In the system parameter setting interface, short press the SET button to switch the system parameters to change, and short press the UP/DOWN button to change it.
●OP / CL parameter change interface, short press the STOP, to switch the timing unit (1s / 0.1s / 0.01s / 1min)
Once all parameters are completed, press and hold the SET button to save the parameter settings and exit the setting interface.

(Movement Details by Mode)
P1: After the signal is triggered, the relay is going to OP time and then disconnect. In OP, when the signal is triggered again in the OP.

P2: After the signal is triggered, the relay will go within the OP time and then disconnect. Timing will be re-adjusted when the signal is triggered again in OP.

P3: After the signal is triggered, the relay is going to OP time and then disconnect. During the OP time, reset, relay disconnection, timing stop signals are triggered again.

P4: Relay lead in OP time after the relay is disconnected from CL time after trigger signal. Cut the relay after the time is completed.

P5: Disconnect from the relay CL time after the relay is connected with OP time. Then recycle the above action, get the signal again, cut the relay, stop the timing, and repeat the number of cycles. (LOP) can be set.

P6: No need to trigger signal after power on and off. The relay is going in OP. Cut the CL time and loop the above actions. You can set the number of cycles (LOP)

P7: Signal Retention Function: When the signal is triggered, the relay will maintain conductivity. Or timing will be cleared. The relay will be disconnected when the signal is disappeared and OP. There is a different signal during timing, and the timing is cleared.

Additional function a) Automatically hibernation function/low power function: While running, the interface can be opened and closed by holding the STOP button to automatically open and close the sleep function.
(L-P select ON to start high spring function, OFF to turn off the high spring function).
b) Selection of Relay Function: In the operation interface, press STOP immediately when the relay function starts or closed.
"ON" meets the conductivity state, the relay is normally on, "OFF" meets the conductivity state, and the relay is not on. When in "OFF" state, the system flashes "OUT"