Feature(may vary by option.)

●1. With delay on, delay off, self-lock, and trigger delay function
●2.With power reverse protection to prevent damage to the module
●3. The operating voltage is 5V/12V/24V
●4. The delay time can be set arbitrarily from 0.1 seconds to 120 seconds
●5. The parameters can be stored and the settings will not be lost during a power outage

[5V]




[24V]




[12V]





Description

Specifications
Operating voltage: DC 5V, 12V, 24V (optional)
Working current:
<80mA at 5V (<1mA if relay is not working)
<35mA at 12V (1mA when relay is not working)
<18mA at 24V (<1mA when relay is not working)
Load Capacity:
Normal Open Port: DC0-30V/10A, AC0-250V/10A
Normal closed port: DC 0-28V/10A, AC 0-125V/10A
Operating Temperature: -4 to 140°F (-20 to 60°C) (limit temperature: -8 to 154°F (-30 to 70°C).
Size: 2.36*1.38*0.79in
Module Function:
By pressing the button, you can choose one of the following four functions:
Potentiometer adjustment allows you to choose the delay time Delay Time
T1 is adjustable from 0.1 to 120 seconds.
Function F1:
Delay Pull In: After delay T1 from the time of power on and off, at any time
The relay pulls in and sends a high level pulse signal to the X1 interface.
This function can be reset and resumed.
Function F2:
Power on Delay Disconnection: Relay is separated when power on. T1 Time
After off, the relay is separated, and the high level pulse to the X1 interface at any time
It will be given a signal. This function will be reset and restarted.
Function F3:
Relay self-locking mode: High-level pulse signal is relay X1 interface
and the relay is separated and the high level pulse signal separates the relay
Let me know
Function F4:
Level trigger mode: When the power is on, the relay is disconnected, and the X1 interface
Sends a high level signal to the The relay is connected immediately. X1 Inf
The relay will still be drawn after the signal is disappeared. Retrieve time: T1
reached, the relay will close.
Module Interface:
There are 3 terminals in the voltage and signal input of the module.
DC +: DC power supply plus
2. DC-: negative side of DC power
3. X1: Input signal detection interface
The relay load output has three terminals.
1. COM: Common Relay Interface
2. NO:Relay normal open interface
3. NC: Relay Normally Close Interface
Note:
1. Due to the light and screen difference, the items color may be slightly different from the pictures.
2. Please allow 1-3cm differences due to manual measurement.