Feature

●Measuring range: 0 - 100 HBa, equivalent to 25 - 150 HB
●Parameter Bar Call hardness (Hba), other hardness values can be calculated by an experimental curve
●Small size and portable. One hand operation, easy to use. Use anytime within reach
●No support needed. Just test one side of the sample with a hardness tester and no support is required. Suitable for testing large and extra thick work
●Can be used to measure barCall hardness Other hardness values can be calculated from experimental curve. Brinel Hardness (HB), Vickers Hardness (HV), Webster Hardness (HW), Rockwell Hardness (HRB / HRE / HRF / HRH) etc


Description

Product Description

The digital indentation hardness tester is our latest design and development. It features balance positioning, digital display of hardness values, and non-decomposing calibration and adjustment. It has excellent stability, convenient calibration, and high precision detection. It is mainly used in the aluminum processing industry, testing pure aluminum, soft aluminum, thick aluminum alloy, aluminum strips, aluminum rods, aluminum castings, aluminum forging, and aluminum alloy products. It can also be used in the glass steel industry. Associated standards are ASTM B648-00, ASTM HD2583-07, and GB/T3854-2005.

Product Features

*Small size, portable One hand operation, easy to use. You can always use it within reach.

*Wide testing range can test from super soft pure aluminum to especially hard aluminum alloy. Effective testing range equivalent to 25-150HB brinel hardness

* No support needed. Just test one side of the sample with a hardness tester and no support is required. Suitable for testing large and extra thick work.

*Max hold function records the maximum hardness value when measuring.

* Can be used to measure barCall hardnessOther hardness values can be calculated from experimental curve. Brinel Hardness (HB), Vickers Hardness (HV), Webster Hardness (HW), Rockwell Hardness (HRB / HRE / HRF / HRH) etc.

Product Parameters

Parameter: Barcole hardness (Hba), other hardness values can be calculated by an experimental curve.

Measurement range: 0 - 100 HBa, equivalent to 25 - 150 HB

Resolution: 0.1 HBa

Display error: 81-88HBa±1HBa

42-48Hba±2HBa

Reproductivity error: 81-88HBa±1.5HBa

42-48HBa±2.5Hba

Operating temperature: 0 - 50 °C (0 - 50 °C)

Humidity: <80% rh

Size:170x63x82 mm

Power supply: 2 x 1.5vAAA Um-4 battery (battery is not included in the package)

Weight: 13.8 oz (390 g) (not including batteries).